DOVER 100% Silicone Foley Catheters, 30cc, 2-Way, Case
|
|
|
|
|
SKU: D1SFC30CC2W
DOVER™ 100% Silicone Foley Catheters, 30cc, 2-Way
| Reorder # |
Description |
Qty/Case |
|
8887630187 |
18 Fr. |
10 |
|
8887630203 |
20 Fr. |
10 |
|
8887630229 |
22 Fr. |
10 |
|
8887630245 |
24 Fr. |
10 |
|
8887630260 |
26 Fr. |
10 |
Features and Benefits
| Features |
Benefits |
| 100% Silicone Material |
Inert material preferred for medical devices, Less urethral irritation and stricture versus latex material, Less encrustaion compared to latex catheters, 100% Latex-Free |
| Tip -- Smooth, spearately molded, reinforced tip |
Resists buckling |
| Tip -- Deep stylet pocket |
Accepts stylet securely |
| Tip -- Bullet shape |
Eases insertion, less tissue trauma |
| Eyes -- Smooth, hand finished |
No additional urethral trauma |
| Eyes -- Large, oval shaped |
Ideal size for maximum drainage & design will not allow material to obstruct drainage lumen |
| Balloon -- Ribbed balloon |
Increases strength & symmetry |
| Balloon -- Smooth balloon to shaft transition |
Eases insertion |
| Shaft -- Soft, flexible, non-rigid |
Allows for easy insertion, comfortable silicone |
| Shaft -- Round, smooth, uniform French sized surface |
Reduced irritation to urethra, true french sizes |
| Shaft -- 30% larger inflation lumen due to patented extrusion process |
Allows for greater flow rates |
| Shaft -- 21% larger inflation lumen |
Fast, easy insertion |
| Shaft -- One wall construction due to patented extrusion process |
Resists collapsing during forced irrigation |
| Funnel -- Separately molded, ribbed, reinforced |
Assures proper seal to drain bag connector & various irrigation syringes |
| Valve -- Bespak spring-loaded valve |
Provides consistent inflation/deflation of Foley catheter balloon |
Frequently Asked Questions
| Question |
Answer |
| What is the benefit of having a silicone Foley catheter versus a latex Foley catheter? |
The advantage is the silicone material. Silicone is biocompatible. It is non-reactive to human tissue. Silicone is inorganic which is man-made, inert, and contains no extractable chemicals or proteins. Latex is an organic material that also contains numerous extractable chemicals and proteins which act as a good source for bacterial growth. Silicone is non-adherent. It repels urine, water, blood, and most organic materials to reduce the incidence of bacterial attachment and growth. Silicone is non-porous so it does not absorb body fluids. It eliminates "Foley Catheter Expansion" whereas latex is porous (acts like a sponge). Silicone is also 100% latex-free. |
| Do silicone coated latex Foley catheters share the same benefits of the DOVER™ 100% Silicone Foley catheter? |
No. Silicone coated latex Foley catheters still utilize a latex platform and do not share the same benefits of a true, 100% silicone catheter (see above). Silicone coated catheters do not eliminate hypersensitivity concerns because they are still comprised of latex. |
| Is silicone still considered stiff and uncomfortable? |
Silicone actually warms to the body's temperature and eventually molds to the shape of the urethra making it more flexible and comfortable. |
|
|